Petroleum Quality Institute of America

The Petroleum Quality Institute of America (PQIA) is an independent resource for information and insights on the quality and performance of lubricants in the marketplace.  Our mission is to serve the consumer of lubricants by reporting on the quality and integrity of lubricants in themarketplace.

 

Supporters

 

 

 

Valvoline Dex/Merc

 

Purchased in: Advanced Auto Parts, Edison, NJ

Date of purchase: 1/17/2012

 

 

 

 

 

 

The results of the tests conducted on this sample meet the requirements of Dexron III/Mercon

 

 

 

 

 

 

 

 

PETROLEUM QUALITY INSTITUTE OF AMERICA

TEST PROGRAM

 

 



Test Results

The averages shown in the table below are for 10 samples tested in February 2012.
PHYSICAL TESTS Specification Average-a
    Brookfield Viscosity @ -40°C, cSt 20,000 cP Max 17,511 16,736
    Viscosity @ 100ºC, cSt, (ASTM D445) 6.8 cSt Min 7.20 7.44
    Viscosity @ 40ºC, cSt, ASTM D445 - 34.0 36.49
    Flash Point °C (ASTM D92) 170/177°C Min-b 195 196
    Viscosity Index - 182 176
ELEMENTAL ANALYSIS-c      
Additives
    Nitrogen μg/g (ASTM D-5762) - 805 785
    Calcium - 119 272
    Magnesium, ppm - 1 1
    Phosphorus,  ppm - 242 21
    Zinc, ppm - 7 2
    Molybdenum,  ppm - <1 <1
    Barium, ppm - <1 <1
 
    Boron,  ppm - 94 75
    Silicon,  ppm-d - 4 2
    Potassium, ppm - <5 <5
    Manganese, ppm - <1 <1
    Titanium, ppm - <1 <1
    Sulfur, ppm - 838 1,061
    Copper, ppm - <1 <1
    Sodium, ppm - 3 6
    Vanadium, ppm - <1 <1
Contaminants
    Silver, ppm - <1 <1
    Aluminum, ppm - <1 <1
    Chromium, ppm - <1 <1
    Iron, ppm - <1 <1
    Nickel, ppm - <1 <1
    Lead, ppm - <1 <1
    Antimony, ppm - <1 <1
    Tin, ppm - <1 <1

a- Average of 10 samples tested in February 2012.

b- Dexron® III, 170°C minimum, Mercon®, 177 °C minimum.

c-Test Method used for metal analysis is ASTM ASTM D5185.

d- ASTM D5185-09 Reproducibility by element.

 

 

 
Valvoline Dex/Merc
General Motors and Ford Motor Company has set forth a number of laboratory and rig tests required to meet the former Dexron III and Mercon performance specifications. Although laboratory tests alone cannot be used to establish if an ATF meets these specifications, they can be used to determine if it doesn't.

The following is a comparison of the test results for the sample of Valvoline Dex/Merc tested with the Dexron III/Mercon requirements.

 
Viscometrics

 The viscometrics meet the required targets for a for a Dexron III/Mercon ATF.

Viscosity @ 100ºC, cSt, (ASTM D445)
This text is replaced by the Flash movie.
Brookfield Viscosity @ -40°C, cSt 
This text is replaced by the Flash movie.

        

          Flash Point, °C, (ASTM D92)


This text is replaced by the Flash movie.


 
 
 

 
FRONT AND BACK LABELS FROM PRODUCT TESTED