Petroleum Quality Institute of America

The Petroleum Quality Institute of America (PQIA) is an independent resource for information and insights on the quality and performance of lubricants in the marketplace.  Our mission is to serve the consumer of lubricants by reporting on the quality and integrity of lubricants in themarketplace.

 

 

 

 

 

 

CLICK FOR LARGER IMAGE Wolf's Head® DX III-H/M ATF  

Wolf's Head Oil Company, Tampa, FL

 

Purchased in: Quick Shop Express, Newburgh, NY

Date of purchase: 3-1-2013

 

 

The results of the tests conducted on this sample meet the requirements of Dexron III/Mercon.

 

PETROLEUM QUALITY INSTITUTE OF AMERICA

TEST PROGRAM

 

 


Test Results


The averages shown in the table below are for 10 samples tested in February 2012.
PHYSICAL TESTS Specification Average-a
    Brookfield Viscosity @ -40°C, cP 20,000 cP Max 17,511 16,980
    Viscosity @ 100ºC, cSt, (ASTM D445) 6.8 cSt Min 7.20 9.3
    Viscosity @ 40ºC, cSt, ASTM D445 - 34.0 34.7
    Flash Point °C (ASTM D92) 170/177°C Min-b 195 247
    Viscosity Index - 182 268
ELEMENTAL ANALYSIS-c      
Additives
    Calcium - 119 209
    Magnesium, ppm - 1 <1
    Phosphorus,  ppm - 242 171
    Zinc, ppm - 7 <1
    Molybdenum,  ppm - <1 <1
    Barium, ppm - <1 <1
 
    Boron,  ppm - 94 57
    Silicon,  ppm-d - 4 3
    Potassium, ppm - <5 <1
    Manganese, ppm - <1 <1
    Titanium, ppm - <1 <1
    Copper, ppm - <1 <1
    Sodium, ppm - 3 2
    Vanadium, ppm - <1 <1
Contaminants
    Silver, ppm - <1 <1
    Aluminum, ppm - <1 <1
    Chromium, ppm - <1 <1
    Iron, ppm - <1 <1
    Nickel, ppm - <1 <1
    Lead, ppm - <1 <1
    Antimony, ppm - <1 <1
    Tin, ppm - <1 <1

a- Average of 10 samples tested in February 2012.

b- Dexron® III, 170°C minimum, Mercon®, 177 °C minimum.

c-Test Method used for metal analysis is ASTM ASTM D5185.

d- ASTM D5185-09 Reproducibility by element.

 

 

 
Wolf's Head® DX III-H/M ATF
General Motors and Ford Motor Company has set forth a number of laboratory and rig tests required to meet the former Dexron III and Mercon performance specifications. Although laboratory tests alone cannot be used to establish if an ATF meets these specifications, they can be used to determine if it doesn't.

The following is a comparison of the test results for the sample of Wolf's Head® DX III-H/M ATF tested with the Dexron III/Mercon requirements.

 

 
Viscometrics

The viscometrics meet the required targets for a for a Dexron III/Mercon ATF.

        

         

FRONT AND BACK LABELS FROM PRODUCT TESTED