Petroleum Quality Institute of America

The Petroleum Quality Institute of America (PQIA) is an independent resource for information and insights on the quality and performance of lubricants in the marketplace.  Our mission is to serve the consumer of lubricants by reporting on the quality and integrity of lubricants in themarketplace.

 

 

 

 

 

 

 

CLICK FOR LARGER IMAGE Traveller Multi-Purpose ATF

Manufactured exclusively for Tractor Supply Company, Brentwood, TN

 

Purchased in: Tractor Supply Co. Flanders, NJ

Date of purchase: 2-5-2013

 

 

The results of the tests conducted on this sample meet the requirements of Dexron III/Mercon.

 
   

 

PETROLEUM QUALITY INSTITUTE OF AMERICA

TEST PROGRAM

 

 

Test Results

The averages shown in the table below are for 10 samples tested in February 2012.
PHYSICAL TESTS Specification Average-a
    Brookfield Viscosity @ -40°C, cP 20,000 cP Max 17,511 15,660
    Viscosity @ 100ºC, cSt, (ASTM D445) 6.8 cSt Min 7.20 7.2
    Viscosity @ 40ºC, cSt, ASTM D445 - 34.0 34.1
    Flash Point °C (ASTM D92) 170/177°C Min-b 195 217
    Viscosity Index - 182 182
ELEMENTAL ANALYSIS-c      
Additives
    Calcium - 119 109
    Magnesium, ppm - 1 <1
    Phosphorus,  ppm - 242 234
    Zinc, ppm - 7 19
    Molybdenum,  ppm - <1 <1
    Barium, ppm - <1 <1
 
    Boron,  ppm - 94 112
    Silicon,  ppm-d - 4 6
    Potassium, ppm - <5 <1
    Manganese, ppm - <1 <1
    Titanium, ppm - <1 <1
    Copper, ppm - <1 <1
    Sodium, ppm - 3 8
    Vanadium, ppm - <1 <1
Contaminants
    Silver, ppm - <1 <1
    Aluminum, ppm - <1 <1
    Chromium, ppm - <1 <1
    Iron, ppm - <1 <1
    Nickel, ppm - <1 <1
    Lead, ppm - <1 <1
    Antimony, ppm - <1 <1
    Tin, ppm - <1 <1

a- Average of 10 samples tested in February 2012.

b- Dexron® III, 170°C minimum, Mercon®, 177 °C minimum.

c-Test Method used for metal analysis is ASTM ASTM D5185.

d- ASTM D5185-09 Reproducibility by element.

 

 

 
Traveller ATF
General Motors and Ford Motor Company has set forth a number of laboratory and rig tests required to meet the former Dexron III and Mercon performance specifications. Although laboratory tests alone cannot be used to establish if an ATF meets these specifications, they can be used to determine if it doesn't.

The following is a comparison of the test results for the sample of Traveller ATF tested with the Dexron III/Mercon requirements.

 

 
Viscometrics

The viscometrics meet the required targets for a for a Dexron III/Mercon ATF.

Viscosity @ 100ºC, cSt, (ASTM D445)
This text is replaced by the Flash movie.
Brookfield Viscosity @ -40°C, cP 
This text is replaced by the Flash movie.

        

          Flash Point, °C, (ASTM D92)


This text is replaced by the Flash movie.


 
 
 

 
FRONT AND BACK LABELS FROM PRODUCT TESTED