Petroleum Quality Institute of America

The Petroleum Quality Institute of America (PQIA) is an independent resource for information and insights on the quality and performance of lubricants in the marketplace.  Our mission is to serve the consumer of lubricants by reporting on the quality and integrity of lubricants in themarketplace.

 

Supporters

 

 

 

ACE Transmission Fluid Universal Formulation

Ace Hardware Corp., Oak Brook, Il

 

Purchased in: Goodyear Ace Hardware, 610 N Estrella Pkwy, Goodyear, AZ

Date of purchase: 5-12-2012

 

 

The results of the tests conducted on this sample meet the requirements of Dexron III/Mercon

 

 

 

 

 

PETROLEUM QUALITY INSTITUTE OF AMERICA

TEST PROGRAM

 

 



Test Results


The averages shown in the table below are for 10 samples tested in February 2012.
PHYSICAL TESTS Specification Average-a
    Brookfield Viscosity @ -40°C, cP 20,000 cP Max 17,511 18,416
    Viscosity @ 100ºC, cSt, (ASTM D445) 6.8 cSt Min 7.20 7.05
    Viscosity @ 40ºC, cSt, ASTM D445 - 34.0 35.29
    Flash Point °C (ASTM D92) 170/177°C Min-b 195 204
    Viscosity Index - 182 166
ELEMENTAL ANALYSIS-c      
Additives
    Nitrogen μg/g (ASTM D-5762) - 805 705
    Calcium - 119 9
    Magnesium, ppm - 1 2
    Phosphorus,  ppm - 242 139
    Zinc, ppm - 7 3
    Molybdenum,  ppm - <1 <1
    Barium, ppm - <1 <1
 
    Boron,  ppm - 94 51
    Silicon,  ppm-d - 4 2
    Potassium, ppm - <5 <5
    Manganese, ppm - <1 <1
    Titanium, ppm - <1 <1
    Sulfur, ppm - 838 539
    Copper, ppm - <1 <1
    Sodium, ppm - 3 <5
    Vanadium, ppm - <1 <1
Contaminants
    Silver, ppm - <1 <1
    Aluminum, ppm - <1 <1
    Chromium, ppm - <1 <1
    Iron, ppm - <1 <1
    Nickel, ppm - <1 <1
    Lead, ppm - <1 <1
    Antimony, ppm - <1 <1
    Tin, ppm - <1 <1

a- Average of 10 samples tested in February 2012.

b- Dexron® III, 170°C minimum, Mercon®, 177 °C minimum.

c-Test Method used for metal analysis is ASTM ASTM D5185.

d- ASTM D5185-09 Reproducibility by element.

 

 

 
ACE ATF Universal Formulation
General Motors and Ford Motor Company has set forth a number of laboratory and rig tests required to meet the former Dexron III and Mercon performance specifications. Although laboratory tests alone cannot be used to establish if an ATF meets these specifications, they can be used to determine if it doesn't.

The following is a comparison of the test results for the sample of ACE ATF tested with the Dexron III/Mercon requirements.

 

 
Viscometrics

The viscometrics meet the required targets for a for a Dexron III/Mercon ATF.

Viscosity @ 100ºC, cSt, (ASTM D445)
This text is replaced by the Flash movie.
Brookfield Viscosity @ -40°C, cP 
This text is replaced by the Flash movie.

        

          Flash Point, °C, (ASTM D92)


This text is replaced by the Flash movie.


 
 
 

 
FRONT AND BACK LABELS FROM PRODUCT TESTED