Road-Tech Multi Purpose Automatic Transmission Fluid

Marketed by Salado Sales, Inc.

 

Purchased in: Wawa, West Chester, PA

Date of purchase: 6/2/2012

 

Advisory:  The Road-Tech Multi Purpose ATF label states that the product is suitable for use in transmissions where Dexron III or Mercon is recommended. PQIA's test results for this sample exceed the Dexron III and Mercon specification for Brookfield Viscosity @ -40°C of 20,000 cP maximum.

 

 

 

PETROLEUM QUALITY INSTITUTE OF AMERICA

TEST PROGRAM

 

 



Test Results


The averages shown in the table below are for 10 samples tested in February 2012.
PHYSICAL TESTS Specification Average-a
    Brookfield Viscosity @ -40°C, cP 20,000 cP Max 17,511 26,344
    Viscosity @ 100ºC, cSt, (ASTM D445) 6.8 cSt Min 7.20 7.51
    Viscosity @ 40ºC, cSt, ASTM D445 - 34.0 37.39
    Flash Point °C (ASTM D92) 170/177°C Min-b 195 196
    Viscosity Index - 182 173
ELEMENTAL ANALYSIS-c      
Additives
    Nitrogen μg/g (ASTM D-5762) - 805 814
    Calcium - 119 12
    Magnesium, ppm - 1 <1
    Phosphorus,  ppm - 242 159
    Zinc, ppm - 7 6
    Molybdenum,  ppm - <1 <1
    Barium, ppm - <1 <1
 
    Boron,  ppm - 94 60
    Silicon,  ppm-d - 4 4
    Potassium, ppm - <5 <5
    Manganese, ppm - <1 <1
    Titanium, ppm - <1 <1
    Sulfur, ppm - 838 729
    Copper, ppm - <1 <1
    Sodium, ppm - 3 <5
    Vanadium, ppm - <1 <1
Contaminants
    Silver, ppm - <1 <1
    Aluminum, ppm - <1 <1
    Chromium, ppm - <1 <1
    Iron, ppm - <1 <1
    Nickel, ppm - <1 <1
    Lead, ppm - <1 <1
    Antimony, ppm - <1 <1
    Tin, ppm - <1 <1

a- Average of 10 samples tested in February 2012.

b- Dexron® III, 170°C minimum, Mercon®, 177 °C minimum.

c-Test Method used for metal analysis is ASTM ASTM D5185.

d- ASTM D5185-09 Reproducibility by element.

 

 

 
Road-Tech ATF
General Motors and Ford Motor Company has set forth a number of laboratory and rig tests required to meet the former Dexron III and Mercon performance specifications. Although laboratory tests alone cannot be used to establish if an ATF meets these specifications, they can be used to determine if it doesn't.

The following is a comparison of the test results for the sample of Road-Tech ATF tested with the Dexron III/Mercon requirements.

 

 
Viscometrics

The viscometrics do not meet the required targets for a for a Dexron III/Mercon ATF.

Viscosity @ 100ºC, cSt, (ASTM D445)
This text is replaced by the Flash movie.
Brookfield Viscosity @ -40°C, cP 
This text is replaced by the Flash movie.

        

          Flash Point, °C, (ASTM D92)


This text is replaced by the Flash movie.


 
 
 

 
FRONT AND BACK LABELS FROM PRODUCT TESTED